[{"data":1,"prerenderedAt":342},["ShallowReactive",2],{"method-validation-audit-zhu2022liinit":3,"method-zhu2022liinit":4},null,{"method":5,"reference":66,"equipment":86,"figures":117,"results":118},{"id":6,"label":7,"shortName":8,"title":9,"year":10,"era":11,"cluster":12,"scope":13,"keyIdeaZh":14,"keyIdeaEn":15,"fulltextStatus":16,"publicationStatus":17,"recommendation":18,"constructionRelevance":19,"validationEnvironment":20,"strengths":22,"limitations":28,"sensors":34,"platform":37,"estimator":39,"association":40,"timeModel":41,"deskew":42,"loopClosure":43,"globalOptimization":43,"mapRepresentation":44,"prior":45,"outputGeometry":46,"compute":47,"codeUrl":48,"codeLicense":49,"relatedVersions":50,"strengthsZh":54,"limitationsZh":60},"zhu2022liinit","Zhu et al., 2022b","LI-Init","Robust Real-time LiDAR-inertial Initialization",2022,"recent","C13","sensing_calibration_sync_preprocessing","LI-Init 在 LiDAR 慣性里程計啟動前，自動判斷資料激勵是否足夠，並線上估計 LiDAR 與 IMU 的時間偏移、外參、重力向量與 IMU 偏差。時間偏移先以互相關粗估，再與旋轉外參聯合最佳化。作者強調若時間偏移未知，依賴 IMU 的運動畸變補償就無法正確執行。","Online initialization estimating LiDAR-IMU time offset, extrinsics, gravity and biases with excitation checking, feeding FAST-LIO2.","full_text_reviewed","peer_reviewed_published","main_body","未在工地測試；自組手持設備在建築量測常見，未同步時的時間偏移估計直接影響去畸變（推論）。",[21],"controlled_experiment",[23,24,25,26,27],"With artificially shifted IMU timestamps (0.05 to 0.5 s), time-offset RMSE about 1.6 to 3.4 ms on Livox sensors (Table II)","Extrinsic translation error about 0.6 to 1.3 cm mean and rotation error below 1 deg against CAD reference across three LiDARs (Table III)","On two PandarXT sequences (first 40 s): rotation error 0.6208 deg versus 1.0375 deg (LI-Calib) and 0.8483 deg (Target-Free); translation 0.0162 m versus diverged (LI-Calib) and 0.0187 m (Target-Free); 10.2 s versus 332.6 s and 115.7 s (Table IV)","FAST-LIO2 with the LI-Init time offset: end-to-end drift 0.0102 m over an 11.36 m handheld loop, versus 0.246 m with FAST-LIO2 internal synchronization (Sec. IV-A, Fig. 6)","No calibration target, extra sensor, hardware synchronization or stationary start required; an excitation assessment tells the user how to move the device (Sec. I, Sec. II, Sec. III-C.5)",[29,30,31,32,33],"Assumes an unknown but constant time offset (Sec. I contributions, Sec. III-C.2)","Extrinsic error larger for the spinning PandarXT than the Livox units, because frame splitting shrinks the sub-frame FoV so the device must move slowly, lowering IMU excitation and SNR (Table III, Sec. IV-B.1)","Motion-based: needs sufficient excitation, judged by a singular-value threshold, and LiDAR odometry degeneration prevents data from being used (Sec. III-A, Sec. III-C.5)","Ground-truth time offset is unavailable for unsynchronized rigs; temporal accuracy is shown with artificial offsets on factory-synchronized Livox units and indirectly through LIO drift (Sec. IV-A)","Extrinsic accuracy is validated indirectly through a CAD-designed relative pose between two Pixhawk mounting poses; the baseline comparison uses only two PandarXT sequences (Sec. IV-B)",[35,36],"3D LiDAR: Livox Avia (small FoV), Livox Mid360 (non-repetitive scanning), Hesai PandarXT (mechanical spinning); all set to 10 Hz","6-axis IMU Bosch BMI088, both inside the Livox LiDARs (factory hardware-synchronized) and inside a Pixhawk flight controller (unsynchronized with PandarXT); raw data 200 Hz",[38],"handheld","LiDAR odometry with error-state iterated Kalman filter, then cross-correlation temporal alignment and joint temporal-spatial optimization","LiDAR-only odometry uses scan-to-map point-to-plane residuals (modified from FAST-LIO2), chosen over NDT scan-to-scan so that non-repetitive LiDARs are supported; LiDAR and IMU data are associated by cross-correlation of angular-velocity magnitudes, then least-squares alignment of angular velocity and acceleration","Constant angular and linear velocity model between scans, with each input frame split into sub-frames to reduce model mismatch; IMU data linearly interpolated to LiDAR-odometry timestamps; the unknown constant time offset is estimated as an integer number of odometry intervals by cross-correlation and refined by a sub-interval residual using a constant angular acceleration approximation","During initialization, points are deskewed without the IMU: each point is projected to the scan-end frame using the constant-velocity prediction, because the unsynchronized IMU cannot yet be used; Fig. 3 compares Mid360 maps with and without this compensation; after initialization FAST-LIO2 uses the calibrated offset","none","Point map used for scan-to-map registration inside the FAST-LIO2-derived LiDAR odometry; the data structure is not described in this paper","none (initial extrinsic set to identity in tests)","time offset, extrinsic, gravity, IMU bias as initial states for FAST-LIO2","Desktop Intel i7-10700 at 2.90 GHz with 32 GB RAM; LiDAR odometry about 8 ms per sub-frame; initialization solver below 500 ms once data are collected; 10.2 s total calibration on 40 s of PandarXT data versus 332.6 s for LI-Calib and 115.7 s for Target-Free","https:\u002F\u002Fgithub.com\u002Fhku-mars\u002FLiDAR_IMU_Init","GPL-2.0",[51],{"relation":52,"title":9,"doi_or_url":53},"preprint","https:\u002F\u002Farxiv.org\u002Fabs\u002F2202.11006",[55,56,57,58,59],"在人為平移 IMU 時間戳記（0.05 到 0.5 s）的情況下，Livox 感測器上的時間偏移 RMSE 約為 1.6 到 3.4 ms（Table II）","在三款 LiDAR 上，相對於 CAD 參考的外參平移平均誤差約 0.6 到 1.3 cm，旋轉誤差低於 1 deg（Table III）","在兩個 PandarXT 序列（前 40 s）上：旋轉誤差 0.6208 deg，LI-Calib 為 1.0375 deg、Target-Free 為 0.8483 deg；平移 0.0162 m，LI-Calib 發散、Target-Free 為 0.0187 m；耗時 10.2 s，對照 332.6 s 與 115.7 s（Table IV）","FAST-LIO2 採用 LI-Init 的時間偏移後：在 11.36 m 手持迴圈上的起終點漂移為 0.0102 m，使用 FAST-LIO2 內部同步時為 0.246 m（Sec. IV-A, Fig. 6）","不需要校正標靶、額外感測器、硬體同步或靜止起始；激勵評估會告訴使用者如何移動裝置（Sec. I, Sec. II, Sec. III-C.5）",[61,62,63,64,65],"假設時間偏移未知但固定（Sec. I contributions, Sec. III-C.2）","旋轉式 PandarXT 的外參誤差大於 Livox 各機型，因為影格切分縮小了子影格的 FoV，裝置必須緩慢移動，降低 IMU 激勵與 SNR（Table III, Sec. IV-B.1）","以運動為基礎：需要足夠的激勵（以奇異值門檻判斷），且 LiDAR 里程計退化會使資料無法使用（Sec. III-A, Sec. III-C.5）","未同步的設備組合無法取得時間偏移真值；時間準確度是以出廠已同步的 Livox 設備加上人為偏移來展示，並間接透過 LIO 漂移呈現（Sec. IV-A）","外參準確度是透過兩個 Pixhawk 安裝位姿之間經 CAD 設計的相對位姿間接驗證；基線比較僅使用兩個 PandarXT 序列（Sec. IV-B）",{"id":6,"kind":67,"shortName":8,"title":9,"authors":68,"year":10,"venue":72,"venueType":73,"publisher":74,"volumeIssuePages":75,"doi":76,"arxivId":77,"url":53,"firstPublicDate":78,"publicationStatus":17,"metadataStatus":79,"fulltextStatus":16,"era":11,"classicReason":80,"codeUrl":48,"cluster":12,"topics":81,"mdpi":82,"verification":83,"label":7,"fulltextRoute":84,"versionRead":85,"addedByCensus":82},"method",[69,70,71],"Fangcheng Zhu","Yunfan Ren","Fu Zhang","2022 IEEE\u002FRSJ International Conference on Intelligent Robots and Systems (IROS)","conference","IEEE","pp. 3948-3955","10.1109\u002Firos47612.2022.9982225","2202.11006","2022-02-22","metadata_verified","not_applicable",[12],false,"confirmed","arXiv","arXiv 2202.11006v5 (2022-09-15), header 'Accepted for IROS 2022'; not the IEEE version of record",[87,93,98,102,107,112],{"category":88,"model":89,"canonical":89,"role":90,"dataset":3,"specs":91,"locator":92},"lidar","Livox Avia","method input","small FoV, non-repetitive scanning; output set to 10 Hz; built-in BMI088 IMU hardware-synchronized in factory","Fig. 1, Sec. IV, Sec. IV-A, Table II to III",{"category":88,"model":94,"canonical":95,"role":90,"dataset":3,"specs":96,"locator":97},"Livox Mid360","Livox MID-360","non-repetitive scanning; output set to 10 Hz; built-in BMI088 IMU hardware-synchronized in factory","Fig. 1, Sec. IV, Sec. IV-A, Table II to III, Fig. 3, Fig. 8",{"category":88,"model":99,"canonical":99,"role":90,"dataset":3,"specs":100,"locator":101},"Hesai PandarXT","mechanical spinning; output set to 10 Hz; not synchronized with the Pixhawk IMU","Fig. 1, Sec. IV, Sec. IV-A to IV-C, Table III to IV, Fig. 9",{"category":103,"model":104,"canonical":104,"role":90,"dataset":3,"specs":105,"locator":106},"imu","Bosch BMI088","6-axis IMU inside both the Pixhawk flight controller and the Livox LiDARs; raw data 200 Hz","Sec. IV (setup)",{"category":108,"model":109,"canonical":109,"role":90,"dataset":3,"specs":110,"locator":111},"other","Pixhawk flight controller","houses the BMI088 IMU; fixed at two poses I1 and I2 with CAD relative pose of 0 deg rotation and 0.25 m translation (CAD accuracy stated as 0.01 deg and millimetres)","Fig. 1, Sec. IV, Sec. IV-B.1",{"category":113,"model":114,"canonical":114,"role":115,"dataset":3,"specs":116,"locator":106},"compute","Intel i7-10700","compute for runtime","desktop computer, 2.90 GHz, 32 GB RAM; all experiments",[],{"totalRows":119,"groupCount":120,"groups":121,"others":336},35,5,[122,205,263,312],{"slug":123,"group":124,"sourceId":6,"sourceLabel":7,"table":125,"selfRows":126,"metrics":127,"seqs":139,"entrants":152,"cells":156,"outcomes":199,"locators":200,"hardware":201,"wordings":202,"notes":203},"zhu2022liinit-table-ii","zhu2022liinit:Table II","Table II",18,[128,132,135],{"label":129,"unit":130,"statistic":131,"alignment":43},"calibrated time offset Mean[s]","s","mean",{"label":133,"unit":130,"statistic":134,"alignment":43},"time offset RMSE[s]","RMSE",{"label":136,"unit":137,"statistic":138,"alignment":43},"NEES (defined in caption as RMSE divided by the set offset)","%","not_reported",[140,144,146,148,150,151],{"dataset":141,"sequence":142,"environment":143},"authors' handheld sequences (Livox Avia, built-in IMU)","artificial offset 0.05 s","laboratory scene",{"dataset":141,"sequence":145,"environment":143},"artificial offset 0.1 s",{"dataset":141,"sequence":147,"environment":143},"artificial offset 0.5 s",{"dataset":149,"sequence":142,"environment":143},"authors' handheld sequences (Livox Mid360, built-in IMU)",{"dataset":149,"sequence":145,"environment":143},{"dataset":149,"sequence":147,"environment":143},[153],{"name":154,"methodId":6,"linkable":155,"proposed":155,"self":155},"LI-Init (proposed)",true,[157,161,164,167,169,171,173,175,177,179,182,184,186,189,191,193,195,197],[158,158,158,159,160,158,160,160,158],0,0.049,-1,[158,162,158,163,160,158,160,160,158],1,0.0016,[158,165,158,166,160,158,160,160,158],2,3.2,[158,158,162,168,160,158,160,160,158],0.0988,[158,162,162,170,160,158,160,160,158],0.0017,[158,165,162,172,160,158,160,160,158],1.7,[158,158,165,174,160,158,160,160,158],0.4989,[158,162,165,176,160,158,160,160,158],0.0018,[158,165,165,178,160,158,160,160,158],0.36,[158,158,180,181,160,158,160,160,158],3,0.0479,[158,162,180,183,160,158,160,160,158],0.0034,[158,165,180,185,160,158,160,160,158],6.8,[158,158,187,188,160,158,160,160,158],4,0.0982,[158,162,187,190,160,158,160,160,158],0.0028,[158,165,187,192,160,158,160,160,158],2.8,[158,158,120,194,160,158,160,160,158],0.4984,[158,162,120,196,160,158,160,160,158],0.0029,[158,165,120,198,160,158,160,160,158],0.58,[],[125],[],[],[204],"Temporal initialization with artificial IMU timestamp shifts on Livox LiDARs with built-in IMUs; 5 laboratory sequences per LiDAR; true offset about 0 s (factory sync) plus the added shift",{"slug":206,"group":207,"sourceId":6,"sourceLabel":7,"table":208,"selfRows":209,"metrics":210,"seqs":222,"entrants":230,"cells":232,"outcomes":257,"locators":258,"hardware":259,"wordings":260,"notes":261},"zhu2022liinit-table-iii","zhu2022liinit:Table III","Table III",12,[211,214,217,220],{"label":212,"unit":213,"statistic":131,"alignment":43},"relative error Rot(deg), mean","deg",{"label":215,"unit":213,"statistic":216,"alignment":43},"relative error Rot(deg), SD","std",{"label":218,"unit":219,"statistic":131,"alignment":43},"relative error Trans(m), mean","m",{"label":221,"unit":219,"statistic":216,"alignment":43},"relative error Trans(m), SD",[223,226,228],{"dataset":224,"sequence":225,"environment":138},"authors' handheld sequences (Pixhawk IMU at poses I1 and I2)","5 sequences, Livox Mid360",{"dataset":224,"sequence":227,"environment":138},"5 sequences, Livox Avia",{"dataset":224,"sequence":229,"environment":138},"5 sequences, Hesai PandarXT",[231],{"name":154,"methodId":6,"linkable":155,"proposed":155,"self":155},[233,235,237,239,241,243,245,247,249,251,253,255],[158,158,158,234,160,158,160,160,158],0.2472,[158,162,158,236,160,158,160,160,158],0.2043,[158,165,158,238,160,158,160,160,158],0.0081,[158,180,158,240,160,158,160,160,158],0.0075,[158,158,162,242,160,158,160,160,158],0.4019,[158,162,162,244,160,158,160,160,158],0.1708,[158,165,162,246,160,158,160,160,158],0.0064,[158,180,162,248,160,158,160,160,158],0.0069,[158,158,165,250,160,158,160,160,158],0.7244,[158,162,165,252,160,158,160,160,158],0.5076,[158,165,165,254,160,158,160,160,158],0.0133,[158,180,165,256,160,158,160,160,158],0.0102,[],[208],[],[],[262],"Extrinsic initialization: absolute error of the relative pose between two Pixhawk IMU mounting poses (from two LI-Init calibrations) against the CAD design (0 deg, 0.25 m); mean and SD over 5 sequences per LiDAR; initial extrinsic set to identity",{"slug":264,"group":265,"sourceId":6,"sourceLabel":7,"table":266,"selfRows":180,"metrics":267,"seqs":274,"entrants":279,"cells":287,"outcomes":303,"locators":305,"hardware":307,"wordings":309,"notes":310},"zhu2022liinit-table-iv","zhu2022liinit:Table IV","Table IV",[268,270,272],{"label":269,"unit":213,"statistic":131,"alignment":43},"Rotation(deg)",{"label":271,"unit":219,"statistic":131,"alignment":43},"Translation(m)",{"label":273,"unit":130,"statistic":138,"alignment":80},"Time(s), total calibration time",[275],{"dataset":276,"sequence":277,"environment":278},"two PandarXT plus Pixhawk sequences from Sec. IV-B.1","first 40 s of each sequence","calibration scene of Fig. 7(e) (not described further)",[280,282,285],{"name":281,"methodId":6,"linkable":155,"proposed":155,"self":155},"Proposed",{"name":283,"methodId":284,"linkable":155,"proposed":82,"self":82},"LI-Calib [14]","lv2020licalib",{"name":286,"methodId":3,"linkable":82,"proposed":82,"self":82},"Target-Free [15]",[288,290,292,294,295,297,299,301],[158,158,158,289,160,158,160,160,158],0.6208,[158,162,158,291,160,158,160,160,158],0.0162,[158,165,158,293,160,158,158,160,158],10.2,[162,162,158,3,158,162,160,160,158],[162,165,158,296,160,158,158,160,158],332.6,[165,158,158,298,160,158,160,160,158],0.8483,[165,162,158,300,160,158,160,160,158],0.0187,[165,165,158,302,160,158,158,160,158],115.7,[304],"diverged (refinement fails; authors attribute it to missing gravity initialization)",[266,306],"Table IV and note",[308],"desktop Intel i7-10700 @2.90 GHz, 32 GB RAM",[],[311],"Extrinsic calibration comparison on two Hesai PandarXT plus Pixhawk sequences, first 40 s (400 scans) each; average relative IMU pose error against CAD; time offset pre-compensated for the baselines; default baseline parameters; all on the i7-10700 desktop",{"slug":313,"group":314,"sourceId":6,"sourceLabel":7,"table":315,"selfRows":162,"metrics":316,"seqs":319,"entrants":324,"cells":327,"outcomes":329,"locators":330,"hardware":332,"wordings":333,"notes":334},"zhu2022liinit-text-sec-iv-a","zhu2022liinit:Text Sec.IV-A","Text Sec.IV-A",[317],{"label":318,"unit":219,"statistic":138,"alignment":80},"odometry end-to-end drift over a 11.3627 m trajectory",[320],{"dataset":321,"sequence":322,"environment":323},"authors' handheld sequence (Hesai PandarXT plus Pixhawk IMU)","55.8 s loop, 11.3627 m trajectory","laboratory",[325],{"name":326,"methodId":6,"linkable":155,"proposed":155,"self":155},"FAST-LIO2 with time offset calibrated by LI-Init",[328],[158,158,158,256,160,158,160,160,158],[],[331],"Sec. IV-A, Fig. 6",[],[],[335],"FAST-LIO2 rerun on an unsynchronized Hesai PandarXT plus Pixhawk handheld sequence (55.8 s, device waved and returned to origin; first 20 s used for LI-Init temporal calibration), extrinsic from CAD in both runs",[337],{"group":338,"slug":339,"sourceLabel":7,"table":340,"selfRows":162,"datasets":341},"zhu2022liinit:Text Sec.IV-C","zhu2022liinit-text-sec-iv-c","Text Sec.IV-C",[138],1792180237567]