CELLO-3D
作者先檢視既有封閉形式共變異數估計在 3D 資料上的限制,再以資料驅動方式學習 ICP 配準的共變異數。訓練與評估使用超過五百萬次配準、1020 組真實點雲對,涵蓋結構化與非結構化、室內與室外環境。
本頁內容
Learns ICP registration covariance from large-scale real registrations after showing the limits of closed-form estimators on 3D data.
技術屬性
欄位內容為文獻擷取紀錄的原文用語(英文),以原文為據;「未查證」表示本站尚未讀到該資訊,不代表該方法不具備此能力。
| 感測輸入 | 3D point clouds from the 'Challenging data sets for point cloud registration algorithms' (Pomerleau et al. 2012); the sensor is not named in this paper |
|---|---|
| 原文測試平台 | offline evaluation on recorded public datasets (no platform named in this paper) |
| 狀態估計 | CELLO-style kernel-weighted average of training covariances; an upper-triangular distance metric is learned by SGD with a determinant-plus-trace loss; descriptors per cell of a 4x4x4 grid (25 m x 25 m x 10 m) over the overlap region hold planarity, cylindricality and a 9-bin normal histogram; training covariances come from 5000 ICP samples per pair filtered with DBSCAN |
| 資料關聯 | point-to-plane ICP configured in the framework of Pomerleau et al. [24]: maximum-density and random subsampling filters, k-d tree 3-nearest-neighbour matching, trimmed-distance outlier filter keeping the closest 70%, at most 80 iterations |
| 時間表示 | 不適用 |
| 去畸變 | 原文未報告 |
| 迴圈閉合 | 不適用 |
| 全域最佳化 | none |
| 地圖表示 | 不適用 |
| 先驗資訊 | none |
| 可輸出幾何 | registration covariance |
| 計算需求 | training covariances from about 5,100,000 registrations on 1020 pairs computed on Compute Canada clusters in about 5 CPU-years; online inference time not reported |
使用設備
原文使用的感測器、運算硬體與載具(equipment)。型號保留原文寫法,連結到設備頁中同一型號的歸併名稱;角色依原文用途分為方法輸入、資料集感測器、執行運算平台、參考或真值量測(reference or ground truth)與比較對象設備。
| 類別 | 型號(原文寫法) | 角色 | 資料集 | 原文規格 | 出處 |
|---|---|---|---|---|---|
| 運算硬體 | Compute Canada computing clusters | 執行運算平台 | 未標示 | about 5 CPU-years for about 5,100,000 training registrations (offline data generation, not online runtime) | (Landry et al., 2019, Sec. V-A) |
優勢、限制與查核補充
以下各點包括文獻擷取紀錄及本站查核補充。原文主張與本站分析請依各點的來源、定位及查核範圍區分;原式或數值的核對不等於完整實驗重現。
優勢
- 在全部七個測試組上,平均 KL 散度皆低於平均共變異數基準方法,室內的增益最大,例如 Apartment 為 26.6 相較於 34.1(Table II)
- Censi 的閉式估計平均 KL 散度為 2.25e6 至 2.06e8,因為其估計值小了數個數量級(Table II,Sec. VI-A)
- 每個資料集 100 條軌跡的最終里程計位姿,其平均 Mahalanobis 距離介於 0.405 與 2.50 之間,作者判斷整體而言具一致性(Table III,Sec. VI-B)
限制
- 在自相似環境(Wood、Gazebo)中,相對基準方法的增益有限,這些環境中學得的權重趨近均勻(Sec. VI-A)
- 在 Stairs 與 Apartment 上估計偏向悲觀(平均 DM 低於 1.5)(Sec. VI-B)
- 在 SE(3) 中將 ICP 結果視為常態分布容易出錯,因為觀察到的分布主要為多峰,且描述子品質至關重要(Sec. VII)
- 資料擴增僅繞 z 軸旋轉(2.5D),且每個測試組是以同類型環境的另一個資料集訓練(Sec. V-A, VI,Table II)
營建工程相關證據
原文未報告
原文驗證環境:公開基準、已完工建築、獨立參考量測
報告的性能數據
以下是原文作者報告的性能數值(author-reported results),不是本站重新量測的結果。每張圖只並列同一個比較組(comparison group,同一張表、同一組實驗設定)內的方法;不同比較組之間的數值不可直接比較,也不構成排名。原表中只由感測器本身得到的基準(例如只用 IMU 的姿態、輪式里程計或 GNSS 接收機的定位結果)不是方法,不列入圖表與紀錄數。
本方法共出現在 3 個比較組,合計 58 筆紀錄。
Landry et al., 2019 · Table III 本方法 35 筆
表格設定(擷取紀錄原文):ICP odometry over whole sequence, initial guesses sampled with a = 0.05; final pose error and Mahalanobis distance DM against ground truth; DM averaged over 100 trajectories (Landry et al., 2019, Table III)
final translation error ||u||,Challenging data sets (ETH) · Apartment (22 m)
這張表在此指標與資料序列只列出本方法一筆,沒有可並列的其他方法,因此不畫圖,數值與出處見下表。這是 Landry et al., 2019 在此表設定下報告的數值(author-reported results),不代表方法在其他資料或設定下的表現。
| 方法(原文寫法) | 報告值 | 出處 |
|---|---|---|
| CELLO-3D (ICP odometry)本方法原文提出 | 0.115 m | (Landry et al., 2019, Table III) |
Brossard et al., 2020 · Table 2 本方法 16 筆
表格設定(擷取紀錄原文):Trajectory consistency: Mahalanobis distance of compounded ICP trajectories to ground truth, averaged over 40 initial trajectories per sequence; target 1, below 1 pessimistic; CELLO-3D reproduced from Landry et al. with a slightly different ICP setting (Brossard et al., 2020, Table 2)
Mah. dist. trans.,Challenging data sets for point cloud registration (Pomerleau et al. 2012) · Apartment
只並列這張表在相同設定下報告的方法;以「本方法:」開頭者為本頁方法。失敗、未執行與未報告以標記呈現,不是 0。
按 Tab 進入圖表後,用上下方向鍵逐一瀏覽各類別,Esc 關閉提示框;也可開啟表格檢視閱讀全部數值。
這些是 Brossard et al., 2020 在此表設定下報告的數值(author-reported results),只能在同一個比較組內對照,不代表方法在其他資料或設定下的表現。
資料來源作者報告值(Brossard et al., 2020, Table 2)
| 方法(原文寫法) | 報告值 | 出處 |
|---|---|---|
| CELLO-3D本方法 | 0.2 | (Brossard et al., 2020, Table 2) |
| ini.+ICP (fusion without cross-covariance) | 3.5 | (Brossard et al., 2020, Table 2) |
| proposed (full ML covariance, Eq. 15)原文提出 | 2.3 | (Brossard et al., 2020, Table 2) |
Landry et al., 2019 · Table II 本方法 7 筆
指標Avg. KL divergence
表格設定(擷取紀錄原文,這些數值分屬表中不同部分):(Landry et al., 2019, Table II)
- Average KL divergence between sampled and predicted ICP covariance per test group; trained on the named other group
- Average KL divergence per test group
Avg. KL divergence,Challenging data sets (ETH) · Apartment (trained on Haupt. and Stairs; 1190 pairs)
只並列這張表在相同設定下報告的方法;以「本方法:」開頭者為本頁方法。失敗、未執行與未報告以標記呈現,不是 0。
按 Tab 進入圖表後,用上下方向鍵逐一瀏覽各類別,Esc 關閉提示框;也可開啟表格檢視閱讀全部數值。
這些是 Landry et al., 2019 在此表設定下報告的數值(author-reported results),只能在同一個比較組內對照,不代表方法在其他資料或設定下的表現。
資料來源作者報告值(Landry et al., 2019, Table II)
| 方法(原文寫法) | 報告值 | 出處 |
|---|---|---|
| Baseline (mean training covariance) | 34.1 | (Landry et al., 2019, Table II) |
| Ours (CELLO-3D)本方法原文提出 | 26.6 | (Landry et al., 2019, Table II) |
| Censi | 91900000 | (Landry et al., 2019, Table II) |
來源
Landry et al., 2019
(2019)CELLO-3D: Estimating the Covariance of ICP in the Real World2019 International Conference on Robotics and Automation (ICRA), pp. 8190-8196
DOI 10.1109/icra.2019.8793516arXiv 1810.01470
同儕審查已出版已讀全文公式與數值:全面查核未完成近十年
相關版本
- 預印本:CELLO-3D: Estimating the Covariance of ICP in the Real World https://arxiv.org/abs/1810.01470