[{"data":1,"prerenderedAt":105},["ShallowReactive",2],{"method-validation-audit-laconte2019lidarbias":3,"method-laconte2019lidarbias":4},null,{"method":5,"reference":58,"equipment":78,"figures":104,"results":3},{"id":6,"label":7,"shortName":8,"title":9,"year":10,"era":11,"cluster":12,"scope":13,"keyIdeaZh":14,"keyIdeaEn":15,"fulltextStatus":16,"publicationStatus":17,"recommendation":18,"constructionRelevance":19,"validationEnvironment":20,"strengths":24,"limitations":28,"sensors":33,"platform":36,"estimator":39,"association":40,"timeModel":40,"deskew":40,"loopClosure":40,"globalOptimization":41,"mapRepresentation":40,"prior":41,"outputGeometry":42,"compute":43,"codeUrl":3,"codeLicense":44,"relatedVersions":45,"strengthsZh":49,"limitationsZh":53},"laconte2019lidarbias","Laconte et al., 2019","Incidence-angle LiDAR bias model","Lidar Measurement Bias Estimation via Return Waveform Modelling in a Context of 3D Mapping",2019,"recent","C13","sensing_calibration_sync_preprocessing","作者質疑 LiDAR 量測為零均值高斯雜訊的常見假設，指出與入射角及距離相關的偏差會造成可預期的定位漂移，例如直線隧道的地圖會依靠近哪一側牆而彎曲。本文以回波波形建模解釋此偏差，於實驗裝置量測三款 LiDAR 的偏差，發現高入射角下可達 20 cm，並用模型修正量測以改善地圖與漂移。","Models incidence-angle and range dependent LiDAR bias via return-waveform physics, measures it for three LiDARs (up to 20 cm), and corrects maps and drift.","full_text_reviewed","peer_reviewed_published","main_body","未在工地測試；隧道與長走廊的高入射角量測與營建地下工程及室內走廊高度相關（推論）。",[21,22,23],"controlled_experiment","underground_or_tunnel","independent_reference",[25,26,27],"Bias correction reduced map bending and localization drift in a long straight underground corridor example (Sec. I, Fig. 1)","A physical waveform model with only two per-sensor scale factors was fitted to bench data at depths 1 to 10 m and incidence angles 0 to 85 degrees for three LiDARs (Sec. IV, V, Table I)","Unlike the empirical model of Pfister et al., the analytic model captures the angle-dependent slope of bias with depth, and it needs fewer samples and extrapolates better than a non-parametric kernel fit (Sec. V)",[29,30,31,32],"Normals used for incidence angle should be estimated iteratively with bias taken into account (Sec. VI, future work)","Map improvements are shown only qualitatively; no quantitative drift or map error is reported (Sec. V, Figs. 1 and 9)","3D corrections were noisy at long range because normals from sparse HDL-32E data give unreliable incidence angles (Sec. V, Fig. 9)","Bench measurements beyond 10 m were unreliable because the beam exceeded the 0.6 m board at high angles, and residual setup misalignment may remain (Sec. IV)",[34,35],"2D LiDAR (SICK LMS151)","3D LiDAR (Velodyne HDL-32E, Robosense RS-LiDAR-16)",[37,38],"mobile robot carrying the LiDAR in a university tunnel (robot type not stated in the text read)","controlled test bench (linear motion table)","not_applicable (measurement model and correction)","not_applicable","none","bias-corrected range measurements and maps","closed-form correction implemented in libpointmatcher; authors state the computation is lightweight and does not affect mapping performance; no timings reported","not_verified",[46],{"relation":47,"title":9,"doi_or_url":48},"preprint","https:\u002F\u002Farxiv.org\u002Fabs\u002F1810.01619",[50,51,52],"在一段長直地下走廊的範例中，偏差校正減少了地圖彎曲與定位漂移（Sec. I，Fig. 1）","針對三具 LiDAR，以僅含兩個逐感測器尺度因子的物理波形模型，擬合深度 1 至 10 m、入射角 0 至 85 度的實驗台資料（Sec. IV, V，Table I）","與 Pfister et al. 的經驗模型不同，此解析模型能捕捉偏差隨深度變化且與角度相關的斜率，且比非參數核擬合所需樣本更少、外插表現更好（Sec. V）",[54,55,56,57],"用於計算入射角的法向量應在考量偏差的情況下以迭代方式估計（Sec. VI，未來工作）","地圖改善僅以定性方式呈現；未報告定量的漂移或地圖誤差（Sec. V，Figs. 1 and 9）","在長距離處三維校正結果帶有雜訊，因為由稀疏 HDL-32E 資料估計的法向量給出不可靠的入射角（Sec. V，Fig. 9）","超過 10 m 的實驗台量測不可靠，因為在大角度時光束超出 0.6 m 的板面，且可能仍殘留架設上的未對準（Sec. IV）",{"id":6,"kind":59,"shortName":8,"title":9,"authors":60,"year":10,"venue":65,"venueType":66,"publisher":67,"volumeIssuePages":68,"doi":69,"arxivId":70,"url":48,"firstPublicDate":71,"publicationStatus":17,"metadataStatus":72,"fulltextStatus":16,"era":11,"classicReason":40,"codeUrl":3,"cluster":12,"topics":73,"mdpi":74,"verification":75,"label":7,"fulltextRoute":76,"versionRead":77,"addedByCensus":74},"component",[61,62,63,64],"Johann Laconte","Simon-Pierre Deschenes","Mathieu Labussiere","Francois Pomerleau","2019 International Conference on Robotics and Automation (ICRA)","conference","IEEE","pp. 8100-8106","10.1109\u002Ficra.2019.8793671","1810.01619","2018-10-03","metadata_verified",[12],false,"corrected","arXiv","arXiv v2 (2019-08-28), IEEE copyright notice in arXiv comments; VoR (ICRA 2019) not compared",[79,86,90,94,100],{"category":80,"model":81,"canonical":82,"role":83,"dataset":3,"specs":84,"locator":85},"lidar","Sick LMS151","SICK LMS-151","method input","2D LiDAR; fitted aperture half-angle 0.43 deg (Table I)","Sec. IV, V, Table I, Fig. 1",{"category":80,"model":87,"canonical":87,"role":83,"dataset":3,"specs":88,"locator":89},"Velodyne HDL-32E","3D LiDAR; fitted aperture half-angle 0.085 deg (Table I); mounted on the robot for the 3D tunnel map","Sec. IV, V, Table I, Fig. 9",{"category":80,"model":91,"canonical":91,"role":83,"dataset":3,"specs":92,"locator":93},"Robosense RS-LiDAR-16","3D LiDAR lent by Robosense; fitted aperture half-angle 0.085 deg (Table I)","Sec. IV, V, Table I",{"category":95,"model":96,"canonical":96,"role":97,"dataset":3,"specs":98,"locator":99},"other","Renishaw XL-80 interferometer","reference or ground truth","ground-truth board distance with accuracy of the order of 1 micrometre","Sec. IV, Figs. 5-6",{"category":95,"model":101,"canonical":101,"role":97,"dataset":3,"specs":102,"locator":103},"linear motion table (rail) with rotating wooden board","rail of about 30 m; board 0.6 x 0.6 m on a graduated disc; 12 board orientations (0 to 60 deg in 10 deg steps, 65 to 85 deg in 5 deg steps) at 8 depths from 1 to 10 m; 45 s per setting; metrology room at 20 C","Sec. IV, Fig. 5",[],1792180233341]