[{"data":1,"prerenderedAt":169},["ShallowReactive",2],{"method-validation-audit-hong2010vicp":3,"method-hong2010vicp":4},null,{"method":5,"reference":57,"equipment":77,"figures":91,"results":92},{"id":6,"label":7,"shortName":8,"title":9,"year":10,"era":11,"cluster":12,"scope":13,"keyIdeaZh":14,"keyIdeaEn":15,"fulltextStatus":16,"publicationStatus":17,"recommendation":18,"constructionRelevance":19,"validationEnvironment":20,"strengths":23,"limitations":28,"sensors":33,"platform":35,"estimator":37,"association":38,"timeModel":39,"deskew":40,"loopClosure":41,"globalOptimization":41,"mapRepresentation":42,"prior":41,"outputGeometry":43,"compute":44,"codeUrl":3,"codeLicense":45,"relatedVersions":46,"strengthsZh":47,"limitationsZh":52},"hong2010vicp","Hong et al., 2010","VICP","VICP: Velocity updating iterative closest point algorithm",2010,"classic","C13","registration_component","一般 ICP 假設同一次掃描的點同時量測，但測距儀是逐點依序量測，快速運動時會產生掃描畸變並累積追蹤誤差。VICP 假設掃描期間速度固定，以前後兩次掃描的相對轉換估計測距儀的本體速度，據以校正每個點後重跑 ICP，再更新速度直到收斂；採用以最後一點為基準的反向補償，使位姿不因掃描時間而延遲，並依感測範圍剔除沒有對應的點。作者以 2D Hokuyo 測距儀在模擬與辦公室推車實驗中驗證（Sec. IV 至 VI）。","Estimates rangefinder velocity during ICP iterations to compensate scan distortion caused by sequential point acquisition.","full_text_reviewed","peer_reviewed_published","background","not_reported",[21,22],"simulation","completed_building",[24,25,26,27],"Lower return-to-start drift than original ICP in all four office experiments, e.g. 177 mm and 7.28 deg versus 2191 mm and 58.14 deg in experiment 1 (Table II)","Advantage is largest for faster motion (experiment 2 at about 2.7 m\u002Fs average: 65 mm versus 2014 mm) (Sec. VI, Table II)","Total computation grows by less than twice that of ICP (Sec. IV-C, Fig. 5)","Backward compensation yields an up-to-date pose (Sec. IV-B)",[29,30,31,32],"Assumes constant velocity during one scan (Sec. IV-B)","Convergence of the velocity iteration is observed but not proven (Sec. IV-B)","Real-world accuracy judged only by return-to-start drift because ground truth was unavailable (Sec. VI)","Tested only with a 2D rangefinder, in simulation and in one small office (Sec. V, VI)",[34],"2D laser rangefinder (Hokuyo URG-04LX, written HOKUYO URG04-LX)",[21,36],"cart pushed by a person carrying the rangefinder and a laptop in an office (7.2 m x 7.8 m)","ICP with velocity update","2D point-to-point closest-point ICP solved by SVD (Algorithm 1), with points outside the pie-shaped sensing area of the previous scan rejected as outliers","constant velocity within a scan","each point transformed with the constant body velocity estimated from the relative ICP transform (backward difference over the scan interval) and re-estimated in an outer loop until the velocity converges; backward compensation uses the last point as reference so the pose is not delayed by the scan time","none","not_applicable","2D rangefinder trajectory and motion-compensated scans","C++ on a laptop with an Intel dual core 2.0 GHz CPU; total cost grows by less than twice that of ICP because ICP iterations drop as the velocity converges; no timings reported","not_verified",[],[48,49,50,51],"在全部四項辦公室實驗中，回到起點的漂移皆低於原始 ICP，例如實驗 1 為 177 mm 與 7.28 deg，原始 ICP 為 2191 mm 與 58.14 deg（Table II）。","運動較快時優勢最大（實驗 2 平均速度約 2.7 m\u002Fs：65 mm 對 2014 mm）（Sec. VI，Table II）。","總計算量增加後仍低於 ICP 的兩倍（Sec. IV-C，Fig. 5）。","反向補償可得到最新時刻的位姿（Sec. IV-B）。",[53,54,55,56],"假設單次掃描期間速度恆定（Sec. IV-B）。","速度迭代的收斂僅為觀察所得，並未經證明（Sec. IV-B）。","由於沒有真值，真實環境準確度僅以回到起點的漂移判斷（Sec. VI）。","僅以二維測距儀在模擬及一間小型辦公室中測試（Sec. V, VI）。",{"id":6,"kind":58,"shortName":8,"title":9,"authors":59,"year":10,"venue":63,"venueType":64,"publisher":65,"volumeIssuePages":66,"doi":67,"arxivId":3,"url":68,"firstPublicDate":69,"publicationStatus":17,"metadataStatus":70,"fulltextStatus":16,"era":11,"classicReason":71,"codeUrl":3,"cluster":12,"topics":72,"mdpi":73,"verification":74,"label":7,"fulltextRoute":75,"versionRead":76,"addedByCensus":73},"component",[60,61,62],"Seungpyo Hong","Heedong Ko","Jinwook Kim","2010 IEEE International Conference on Robotics and Automation","conference","IEEE","pp. 1893-1898","10.1109\u002Frobot.2010.5509312","https:\u002F\u002Fdoi.org\u002F10.1109\u002FROBOT.2010.5509312","2010-05","metadata_verified","necessary technical node: first widely cited ICP variant that estimates sensor velocity inside ICP to compensate intra-scan motion distortion from sequential range measurement.",[12],false,"confirmed","NTU institutional (Chrome)","IEEE Xplore version of record PDF (ICRA 2010, pp. 1893-1898, 6 pages), text extracted in the browser",[78,85],{"category":79,"model":80,"canonical":81,"role":82,"dataset":3,"specs":83,"locator":84},"lidar","HOKUYO URG04-LX","Hokuyo URG-04LX","method input","2D laser scanner; 785 nm; accuracy plus or minus 10 mm; resolution 1 mm; scan angle 240 deg; range 4000 mm; angular resolution 0.36 deg; 100 ms per scan; 50 x 50 x 70 mm; the paper spells the model URG04-LX (the vendor spelling is URG-04LX)","Table I, Sec. V, VI",{"category":86,"model":87,"canonical":87,"role":88,"dataset":3,"specs":89,"locator":90},"compute","laptop with Intel dual core 2.0 GHz CPU","compute for runtime","C++ implementation; no timings reported","Sec. VI",[],{"totalRows":93,"groupCount":94,"groups":95,"others":168},8,1,[96],{"slug":97,"group":98,"sourceId":6,"sourceLabel":7,"table":99,"selfRows":93,"metrics":100,"seqs":108,"entrants":119,"cells":124,"outcomes":161,"locators":162,"hardware":163,"wordings":164,"notes":165},"hong2010vicp-table-ii","hong2010vicp:Table II","Table II",[101,105],{"label":102,"unit":103,"statistic":19,"alignment":104},"R. Error","deg","first-pose",{"label":106,"unit":107,"statistic":19,"alignment":104},"T. Error","mm",[109,113,115,117],{"dataset":110,"sequence":111,"environment":112},"own office experiments","Experiment 1 (curved path, 16.9 s, about 1.2 m\u002Fs)","office room 7.2 m x 7.8 m",{"dataset":110,"sequence":114,"environment":112},"Experiment 2 (curved path, faster, 7.3 s, about 2.7 m\u002Fs)",{"dataset":110,"sequence":116,"environment":112},"Experiment 3 (4.5 m straight forward and back, 25 s)",{"dataset":110,"sequence":118,"environment":112},"Experiment 4 (4.5 m straight forward and back, faster, 15 s)",[120,122],{"name":121,"methodId":3,"linkable":73,"proposed":73,"self":73},"Original ICP",{"name":8,"methodId":6,"linkable":123,"proposed":123,"self":123},true,[125,129,131,133,135,137,139,141,143,146,148,150,152,155,157,159],[126,126,126,127,128,126,128,128,126],0,58.14,-1,[126,94,126,130,128,126,128,128,94],2191,[94,126,126,132,128,126,128,128,94],7.28,[94,94,126,134,128,126,128,128,94],177,[126,126,94,136,128,126,128,128,94],79.98,[126,94,94,138,128,126,128,128,94],2014,[94,126,94,140,128,126,128,128,94],17.06,[94,94,94,142,128,126,128,128,94],65,[126,126,144,145,128,126,128,128,94],2,16.8,[126,94,144,147,128,126,128,128,94],1490,[94,126,144,149,128,126,128,128,94],6.88,[94,94,144,151,128,126,128,128,94],408,[126,126,153,154,128,126,128,128,94],3,54.59,[126,94,153,156,128,126,128,128,94],2942,[94,126,153,158,128,126,128,128,94],3.28,[94,94,153,160,128,126,128,128,94],210,[],[99],[],[],[166,167],"Office experiments with cart-carried URG-04LX; drift error on return to the starting point (no ground truth)","Office experiments; return-to-start drift",[],1792180240295]