[{"data":1,"prerenderedAt":170},["ShallowReactive",2],{"method-validation-audit-hahnel2003_gridfastslam":3,"method-hahnel2003_gridfastslam":4},null,{"method":5,"reference":60,"equipment":82,"figures":101,"results":102},{"id":6,"label":7,"shortName":8,"title":9,"year":10,"era":11,"cluster":12,"scope":13,"keyIdeaZh":14,"keyIdeaEn":15,"fulltextStatus":16,"publicationStatus":17,"recommendation":18,"constructionRelevance":19,"validationEnvironment":20,"strengths":23,"limitations":28,"sensors":33,"platform":36,"estimator":39,"association":40,"timeModel":41,"deskew":42,"loopClosure":43,"globalOptimization":44,"mapRepresentation":45,"prior":44,"outputGeometry":46,"compute":47,"codeUrl":3,"codeLicense":48,"relatedVersions":49,"strengthsZh":50,"limitationsZh":55},"hahnel2003_gridfastslam","Hähnel et al., 2003a","Grid-based FastSLAM with scan matching","An efficient FastSLAM algorithm for generating maps of large-scale cyclic environments from raw laser range measurements",2003,"classic","C01","full_slam_with_global_correction","本文把 Rao-Blackwellized 粒子濾波與雷射掃描匹配結合：每 k 步先以前 k-1 筆掃描與最近的里程計讀值做掃描匹配，得到修正後的里程量測並用於粒子取樣，再以第 k 筆掃描計算粒子權重，使每筆資料只使用一次。掃描匹配殘差以三參數誤差模型描述，參數由 Intel Research Lab 資料學得，因此取樣分布比原始里程計集中得多，所需粒子數與重取樣次數下降，也減輕粒子耗盡，使機器人能閉合大迴圈。每個粒子各有一張佔據網格地圖，但只用與其可視區域相交的有限掃描更新。","Grid-based FastSLAM that converts scan-matching results into corrected odometry with a learned error model before Rao-Blackwellized particle sampling, reducing particle count and depletion so that large loops close with about 100 particles.","full_text_reviewed","peer_reviewed_published","background","未在營建場域驗證；實驗在 Intel Research Lab、University of Washington Sieg Hall 等既有建築與模擬環境中進行，只以目視判斷地圖一致性。以掃描匹配先修正里程再進入粒子濾波的設計，是 FastSLAM [fastslam2002] 與 GMapping [gmapping2007] 之間的方法銜接，對大型建築室內 2D 建圖的迴圈閉合穩健性有參考價值（推論）。",[21,22],"completed_building","simulation",[24,25,26,27],"Globally consistent map of the Intel Research Lab (28 m x 28 m, 491 m traveled) built in real time with 100 samples (Sec. IV.A; Fig. 6).","Consistent real-time map of Sieg Hall (50 m x 12 m) despite repeated loops, with 100 samples and a 10 cm grid (Sec. IV.A; Fig. 8).","In simulation, a single-map posterior approach that keeps only the best particle at loop closure produced inconsistencies, while the proposed method produced a consistent map (Sec. IV.B; Fig. 10).","A standard RBPF without scan-matching correction did not converge on the Intel data with up to 1000 samples (Sec. IV.B).",[29,30,31,32],"The real-time 100-sample map is less sharp than the scan-matching-only map; a crisper 500-particle map took several hours (Sec. IV.A).","Each particle's map is updated from a limited set of scans, an approximation (Sec. III).","The scan-matching error model was learned by treating a map produced by the system itself as ground truth (Sec. III).","(inference) Map quality is judged visually; no metric error against an independent reference is given, and the window k is not stated.",[34,35],"2D laser range finder (SICK LMS)","wheel odometry",[37,38],"wheeled UGV (Pioneer 2)","simulation (B21r simulator)","Rao-Blackwellized particle filter over robot paths with one grid map per particle; every k steps a scan-matching-corrected odometry measurement is computed from the k-1 previous scans and the k most recent odometry readings and used for sampling with a learned three-parameter error model, and the k-th scan weights the particles (Sec. III)","grid-based 2D scan matching of a scan against an occupancy grid built from previous measurements, using a beam-endpoint likelihood (for max-range readings the cell 20 cm before the end is assumed free) (Sec. III)","discrete poses","not_reported","implicit through the particle filter; the scan-matching correction reduces resampling operations and particle depletion so that large loops can be closed (Sec. I, III)","none","2D occupancy grid per particle, updated from a limited number of scans that intersect the particle's visible area (constant-time approximation); 10 cm grid in the Sieg Hall run (Sec. III; Sec. IV.A)","2D occupancy grid map","real time with 100 samples; for the standard RBPF, 200 samples was the real-time limit and 1000 samples the memory limit on a 1.8 GHz Pentium IV PC with 768 MB (Sec. IV)","not_applicable (no code linked in the paper)",[],[51,52,53,54],"以 100 個樣本即時建立 Intel Research Lab（28 m x 28 m，行進 491 m）的全域一致地圖（Sec. IV.A；Fig. 6）。","儘管有重複迴圈，仍以 100 個樣本與 10 cm 格網即時建立 Sieg Hall（50 m x 12 m）的一致地圖（Sec. IV.A；Fig. 8）。","在模擬中，於迴圈閉合時僅保留最佳粒子的單一地圖後驗方法產生不一致，而本方法產生一致的地圖（Sec. IV.B；Fig. 10）。","未經掃描匹配修正的標準 RBPF，在 Intel 資料上使用多達 1000 個樣本仍未收斂（Sec. IV.B）。",[56,57,58,59],"即時的 100 樣本地圖不如僅用掃描匹配的地圖清晰；較清晰的 500 粒子地圖耗時數小時（Sec. IV.A）。","每個粒子的地圖僅由有限的掃描集合更新，屬於近似做法（Sec. III）。","掃描匹配誤差模型是將系統本身產生的地圖視為真值來學習（Sec. III）。","（推論）地圖品質以目視判斷；未提供相對於獨立參考的量化誤差，且未說明視窗 k。",{"id":6,"kind":61,"shortName":8,"title":9,"authors":62,"year":10,"venue":67,"venueType":68,"publisher":69,"volumeIssuePages":70,"doi":71,"arxivId":3,"url":72,"firstPublicDate":73,"publicationStatus":17,"metadataStatus":74,"fulltextStatus":16,"era":11,"classicReason":75,"codeUrl":3,"cluster":12,"topics":76,"mdpi":77,"verification":78,"label":7,"fulltextRoute":79,"versionRead":80,"addedByCensus":81},"method",[63,64,65,66],"Dirk Hähnel","Wolfram Burgard","Dieter Fox","Sebastian Thrun","Proceedings 2003 IEEE\u002FRSJ International Conference on Intelligent Robots and Systems (IROS 2003), Las Vegas, NV","conference","IEEE","vol. 1, pp. 206-211","10.1109\u002Firos.2003.1250629","https:\u002F\u002Fdoi.org\u002F10.1109\u002FIROS.2003.1250629","2003-10","metadata_verified","principle reused: turns scan-matching results into corrected odometry with a learned error model before Rao-Blackwellized particle sampling, cutting particle numbers and depletion; it cites FastSLAM [fastslam2002] and the grid RBPF line later refined by GMapping [gmapping2007] (the lineage is an inference).",[12],false,"corrected","NTU institutional (curl)","IEEE Xplore version of record (scanned PDF with OCR text layer, 6 pp.)",true,[83,88,91,97],{"category":84,"model":85,"canonical":85,"role":86,"dataset":3,"specs":42,"locator":87},"platform","Pioneer 2","method input","Sec. IV.A",{"category":89,"model":90,"canonical":90,"role":86,"dataset":3,"specs":42,"locator":87},"lidar","SICK LMS",{"category":92,"model":93,"canonical":93,"role":94,"dataset":3,"specs":95,"locator":96},"compute","1.8GHz Pentium IV PC","compute for runtime","768 MB main memory","Sec. IV.B",{"category":98,"model":99,"canonical":99,"role":86,"dataset":3,"specs":100,"locator":96},"other","B21r simulator","simulator of a B21r robot used to generate the Wean Hall data (32 m x 10 m, 251 m, noise added to the ground truth)",[],{"totalRows":103,"groupCount":104,"groups":105,"others":169},4,1,[106],{"slug":107,"group":108,"sourceId":6,"sourceLabel":7,"table":109,"selfRows":103,"metrics":110,"seqs":120,"entrants":131,"cells":139,"outcomes":151,"locators":156,"hardware":161,"wordings":162,"notes":163},"hahnel2003-gridfastslam-text-sec-iv","hahnel2003_gridfastslam:Text Sec. IV","Text Sec. IV",[111,114,117],{"label":112,"unit":113,"statistic":42,"alignment":44},"number of samples used for the real-time map","samples",{"label":115,"unit":116,"statistic":42,"alignment":44},"number of particles for the offline map","particles",{"label":118,"unit":119,"statistic":42,"alignment":44},"loop closure outcome","not_applicable",[121,125,128],{"dataset":122,"sequence":123,"environment":124},"Intel Research Lab (Pioneer 2, SICK LMS)","Intel Research Lab log","indoor building",{"dataset":126,"sequence":127,"environment":124},"University of Washington Sieg Hall","Sieg Hall log",{"dataset":129,"sequence":130,"environment":22},"B21r simulator, Wean Hall","simulated run",[132,134,136],{"name":133,"methodId":6,"linkable":81,"proposed":81,"self":81},"proposed RBPF with scan-matching-corrected odometry",{"name":135,"methodId":6,"linkable":81,"proposed":81,"self":81},"proposed RBPF (offline)",{"name":137,"methodId":138,"linkable":81,"proposed":77,"self":77},"particle filter strategy of Thrun et al. [20], [19] (single map)","thrun2000_3dmapping",[140,144,146,148,150],[141,141,141,142,141,141,143,143,141],0,100,-1,[104,104,141,145,104,104,143,143,104],500,[141,141,104,142,141,147,143,143,147],2,[147,147,147,3,147,149,143,143,149],3,[141,147,147,3,149,149,143,143,103],[152,153,154,155],"consistent map in real time","computation took several hours","failed: inconsistencies after closing the loop","consistent map",[157,158,159,160],"Sec. IV.A; Fig. 6","Sec. IV.A; Fig. 9","Sec. IV.A; Fig. 8","Sec. IV.B; Fig. 10",[],[],[164,165,166,167,168],"Intel Research Lab (28 m x 28 m, 491 m traveled); map judged globally consistent and built in real time","Intel Research Lab, offline map with more particles; crisper than the 100-sample map","Sieg Hall fourth floor (50 m x 12 m), several loops, 10 cm grid","Simulated Wean Hall (32 m x 10 m, 251 m, noise added); single-map posterior approach keeping only the best particle at loop closure","Simulated Wean Hall, proposed method",[],1792180240939]