[{"data":1,"prerenderedAt":189},["ShallowReactive",2],{"method-validation-audit-furgale2015ct":3,"method-furgale2015ct":4},null,{"method":5,"reference":71,"equipment":92,"figures":125,"results":126},{"id":6,"label":7,"shortName":8,"title":9,"year":10,"era":11,"cluster":12,"scope":13,"keyIdeaZh":14,"keyIdeaEn":15,"fulltextStatus":16,"publicationStatus":17,"recommendation":18,"constructionRelevance":19,"validationEnvironment":20,"strengths":24,"limitations":29,"sensors":36,"platform":41,"estimator":43,"association":44,"timeModel":45,"deskew":46,"loopClosure":47,"globalOptimization":48,"mapRepresentation":49,"prior":50,"outputGeometry":51,"compute":52,"codeUrl":3,"codeLicense":53,"relatedVersions":54,"strengthsZh":59,"limitationsZh":64},"furgale2015ct","Furgale et al., 2015","Temporal basis functions (continuous-time batch)","Continuous-time batch trajectory estimation using temporal basis functions",2015,"classic","C03","estimation_framework_or_library","作者指出離散時間估計在 IMU、捲簾快門相機或掃描式雷射等高頻感測器下，需為每個量測時間加入位姿變數，使狀態維度過大。本文把完整的 MAP 估計移到連續時間，在高斯假設下推導目標函數，並以少量時間基底函數的係數作為待估狀態，以批次 Gauss-Newton 法求解，再由系統矩陣的逆取得共變異數。論文以三次 B 樣條的矩陣形式實作，旋轉以 Cayley-Gibbs-Rodrigues 參數表示，程式碼已併入 Kalibr 校正工具箱。實驗包含相機與 IMU 外參校正（模擬 1000 次，以及以 Vicon 為參考的實測資料）與捲簾快門相機對圓點圖板的定位，作者並指出節點數量與配置仍是未解問題。","Formulates full MAP estimation in continuous time, representing the trajectory by coefficients of temporal basis functions (cubic B-splines with Cayley-Gibbs-Rodrigues rotations, released in Kalibr), solved by batch Gauss-Newton and validated on camera-IMU calibration and rolling-shutter localization against Vicon.","full_text_reviewed","peer_reviewed_published","background","not_reported。實驗為模擬，以及 Toronto 大學航太研究所（UTIAS）以 Vicon 動作捕捉為參考的手持相機與 IMU 外參校正，另有捲簾快門相機對圓點圖板的定位；未使用 LiDAR，也未評估點雲幾何。作者雖以旋轉式雷射作為連續時間估計的動機，但本文沒有以雷射資料驗證。",[21,22,23],"simulation","controlled_experiment","independent_reference",[25,26,27,28],"Keeps state size tractable for high-rate sensors: 2 min 20 s of data represented with a few hundred knots instead of about 190,200 discrete time-varying states (abstract; Sec. 6.3.2)","Estimated calibration uncertainty matches the error histogram over 1000 simulation trials (Sec. 6.3.1)","The continuous-time model gives a significantly better rolling-shutter motion estimate than the discrete-time model (Sec. 7.3.2)","Derivation structured by increasingly specific assumptions to enable other continuous-time estimators (abstract)",[30,31,32,33,34,35],"Choice of basis and the number and placement of knots remain open; uniform knots can underfit or overfit (Sec. 7.3.1; Sec. 7.4; Sec. 8)","Without a motion model, extra knots overfit rolling-shutter data or let the spline oscillate between global-shutter images (Sec. 7.3.1)","Rolling-shutter estimates degrade under extreme angular motion compared with global shutter (Sec. 7.3.2)","Spline evaluation and Jacobians add computation and produce less sparse block-banded systems than discrete time (Sec. 7.4)","Adaptive knot selection has only been shown offline; online operation is future work (Sec. 7.4; Sec. 8)","Knot selection for spline-based continuous-time methods remains unresolved according to talbot2025ctsurvey (Sec. V-A)",[37,38,39,40],"stereo camera (Point Grey Research Bumblebee XB3, 24 cm baseline) for camera-IMU calibration","IMU (MicroStrain 3DM-GX2)","rolling-shutter camera (Matrix Vision BlueCougar-X102d)","global-shutter camera (Matrix Vision BlueCougar-X012b) used for comparison",[21,42],"handheld (sensor head moved by hand over point landmarks; camera rig waved in front of a dot-pattern board)","batch MAP estimation in continuous time under Gaussian assumptions; state represented by coefficients of cubic B-spline basis functions (Cayley-Gibbs-Rodrigues rotation parameters) and solved by Gauss-Newton; covariance recovered from the inverse of the Gauss-Newton system matrix; white-noise Gaussian-process motion prior acts as regularizer (Secs. 3-6)","known correspondences: point landmarks observed by the camera, with initial camera poses from OpenCV solvePnP (Sec. 6.2); known circle-grid positions on the pattern board (Sec. 7.1); no data-association search is described","continuous-time state (cubic B-spline, uniform knots) with discrete-time measurements, each evaluated at its own timestamp; rolling-shutter measurement time inferred from the image row and the line delay (Eq. 79)","no LiDAR deskew; rolling-shutter distortion handled by evaluating the spline at the capture time of each image row (Sec. 7.1); sweeping lasers discussed only as related work (Sec. 2)","none (batch calibration and localization experiments)","full batch Gauss-Newton over the whole dataset (up to about 2 min 20 s; limited to four iterations in the real-data timing test) (Sec. 6.3.2)","sparse point landmarks estimated in calibration (priors on three landmarks); known dot-grid positions in rolling-shutter localization; no dense map","priors on the positions of three landmarks for observability; a-priori guesses for gravity, landmark positions and the camera-IMU transform (Secs. 6.1-6.2); known pattern-board geometry (Sec. 7.1)","continuous IMU or camera pose trajectory (spline) with covariance, camera-IMU transform, gravity, IMU bias splines and landmark positions (Secs. 6.1, 6.2, 7.1)","offline batch; simulation: three or four Gauss-Newton iterations took about 12 s per trial; real data (1639 stereo images, 14,211 IMU measurements) converged in about 26 s with 300 knots on a MacBook Pro (2.66 GHz Core 2 Duo, 4 GB RAM), dominated by the linear-system solve (Sec. 6.3)","not_applicable",[55],{"relation":56,"title":57,"doi_or_url":58},"conference_version","Continuous-time batch estimation using temporal basis functions (ICRA 2012, pp. 2088-2095; authors Furgale, Barfoot, Sibley)","10.1109\u002FICRA.2012.6225005",[60,61,62,63],"讓高頻感測器的狀態規模維持在可處理範圍：2 min 20 s 的資料以數百個節點表示，而非約 190,200 個離散時變狀態（abstract；Sec. 6.3.2）","在 1000 次模擬試驗中，估計的校正不確定度與誤差直方圖相符（Sec. 6.3.1）","連續時間模型的捲簾快門運動估計顯著優於離散時間模型（Sec. 7.3.2）","推導依逐步具體化的假設建構，以便發展其他連續時間估計器（abstract）",[65,66,67,68,69,70],"基底的選擇以及節點的數量與配置仍是開放問題；均勻節點可能欠擬合或過擬合（Sec. 7.3.1；Sec. 7.4；Sec. 8）","若無運動模型，額外的節點會對捲簾快門資料過擬合，或使樣條在全域快門影像之間振盪（Sec. 7.3.1）","在極端角運動下，捲簾快門的估計相較全域快門會劣化（Sec. 7.3.2）","樣條求值與 Jacobian 會增加計算量，並產生比離散時間更不稀疏的區塊帶狀系統（Sec. 7.4）","自適應節點選擇僅在離線情況下展示；線上運作留待未來研究（Sec. 7.4；Sec. 8）","依 talbot2025ctsurvey，樣條式連續時間方法的節點選擇仍未解決（Sec. V-A）",{"id":6,"kind":72,"shortName":8,"title":9,"authors":73,"year":10,"venue":78,"venueType":79,"publisher":80,"volumeIssuePages":81,"doi":82,"arxivId":3,"url":83,"firstPublicDate":84,"publicationStatus":17,"metadataStatus":85,"fulltextStatus":16,"era":11,"classicReason":86,"codeUrl":3,"cluster":12,"topics":87,"mdpi":88,"verification":89,"label":7,"fulltextRoute":90,"versionRead":91,"addedByCensus":88},"method",[74,75,76,77],"Paul Furgale","Chi Hay Tong","Timothy D. Barfoot","Gabe Sibley","The International Journal of Robotics Research","journal","SAGE","34(14):1688-1710","10.1177\u002F0278364915585860","https:\u002F\u002Fapi.crossref.org\u002Fworks\u002F10.1177\u002F0278364915585860","2012-05","metadata_verified","principle reused: formulating MAP estimation in continuous time with temporal basis functions is the basis of spline-based continuous-time estimators used for high-rate and sweeping sensors.",[12],false,"corrected","NTU institutional (Chrome)","Version of record, IJRR 34(14):1688-1710 (first published online 2015-08-05), SAGE HTML full text read in Chrome with National Taiwan University library access; MathML equations were only partly legible in the extracted text",[93,99,104,110,115,119],{"category":94,"model":95,"canonical":95,"role":96,"dataset":3,"specs":97,"locator":98},"stereo_camera","Point Grey Research Bumblebee XB3","method input","wide-baseline (24 cm) stereo cameras","Fig. 4 caption; Sec. 6.3.2",{"category":100,"model":101,"canonical":101,"role":96,"dataset":3,"specs":102,"locator":103},"imu","MicroStrain 3DM-GX2","not_reported","Fig. 4 caption",{"category":105,"model":106,"canonical":106,"role":107,"dataset":3,"specs":108,"locator":109},"other","Vicon motion capture system","reference or ground truth","tracked the sensor head and landmarks; 200 Hz timestamps used for rolling-shutter evaluation","Fig. 4 caption; Sec. 6.3.2; Fig. 13 caption",{"category":111,"model":112,"canonical":112,"role":96,"dataset":3,"specs":113,"locator":114},"camera","Matrix Vision BlueCougar-X102d","CMOS rolling-shutter camera, 1280 x 960 grayscale at 15 frames per second","Fig. 9 caption; Sec. 7.1",{"category":111,"model":116,"canonical":116,"role":117,"dataset":3,"specs":118,"locator":114},"Matrix Vision BlueCougar-X012b","compared device","CMOS global-shutter camera, 1280 x 960 grayscale at 15 frames per second, synchronized with the rolling-shutter camera",{"category":120,"model":121,"canonical":121,"role":122,"dataset":3,"specs":123,"locator":124},"compute","MacBook Pro","compute for runtime","2.66 GHz Core 2 Duo, 4 GB of 1067 MHz DDR3 RAM","Sec. 6.3.2",[],{"totalRows":127,"groupCount":128,"groups":129,"others":188},3,2,[130,165],{"slug":131,"group":132,"sourceId":6,"sourceLabel":7,"table":133,"selfRows":128,"metrics":134,"seqs":141,"entrants":144,"cells":148,"outcomes":156,"locators":158,"hardware":160,"wordings":161,"notes":162},"furgale2015ct-text-sec-6-3-1","furgale2015ct:Text Sec.6.3.1","Text Sec.6.3.1",[135,138],{"label":136,"unit":137,"statistic":102,"alignment":102},"time to run Gauss-Newton to convergence (three or four iterations) per trial, approximately","s",{"label":139,"unit":140,"statistic":102,"alignment":102},"spread of estimated standard deviations across 1000 trials, as a fraction of the standard deviation","%",[142],{"dataset":21,"sequence":143,"environment":21},"",[145],{"name":146,"methodId":6,"linkable":147,"proposed":147,"self":147},"continuous-time batch estimator (B-spline)",true,[149,153],[150,150,150,151,152,150,152,152,150],0,12,-1,[150,154,150,155,150,150,152,152,154],1,0.2,[157],"other: upper bound, reported as less than 0.2% (the quantity is the max-minus-min spread of estimated standard deviations over 1000 trials)",[159],"Sec. 6.3.1",[],[],[163,164],"Simulated 60 s sinusoidal trajectory, 1000 trials (120 monocular images, 5950 IMU measurements, 300 pose basis functions)","Simulated 60 s sinusoidal trajectory, 1000 trials; spread (maximum minus minimum) of estimated standard deviations relative to their value",{"slug":166,"group":167,"sourceId":6,"sourceLabel":7,"table":168,"selfRows":154,"metrics":169,"seqs":172,"entrants":176,"cells":178,"outcomes":181,"locators":182,"hardware":183,"wordings":185,"notes":186},"furgale2015ct-text-sec-6-3-2","furgale2015ct:Text Sec.6.3.2","Text Sec.6.3.2",[170],{"label":171,"unit":137,"statistic":102,"alignment":102},"time to iterate to convergence with 300 knots, approximately",[173],{"dataset":174,"sequence":143,"environment":175},"UTIAS hand-held calibration dataset","controlled experiment (laboratory with Vicon)",[177],{"name":146,"methodId":6,"linkable":147,"proposed":147,"self":147},[179],[150,150,150,180,152,150,150,152,150],26,[],[124],[184],"MacBook Pro, 2.66 GHz Core 2 Duo, 4 GB RAM",[],[187],"Real calibration dataset of about 2 min 20 s (1639 stereo images, 14,211 IMU measurements), 15 bias knots, pose spline with 300 knots, iterated to convergence",[],1792180239595]